峰值電流的測試條件
是其它負載為額定負載時測試,且脈寬小于 100 毫秒。
1.2.2 Table 3 DC Output Ripple & Noise. (輸出紋波和噪聲)
Output Voltage |
Ripple & Noise (Max.) |
+5.1VSB |
60mVp-p@25℃;200mVp-p@-10℃;150mVp-p when STB |
+5.1V |
60mVp-p@25℃; 150mVp-p@-10℃ |
+12V |
120mVp-p@25℃; 200mVp-p@-10℃ |
+24V |
240mVp-p@25℃; 350mVp-p@-10℃ | Note: 1)Ripple & Noise test: Ripple & Noise bandwidth is set to 20MHz.
紋波和噪聲測試:紋波和噪音帶寬設置在 20 兆赫茲。 2)Use a 0.1uF ceramic capacitor in parallel with a 10uF electrolytic capacitor at output connector terminals for ripple & noise measurements. 輸出端并聯一個 0.1uF 的陶瓷電容和一個 10uF 的電解電容來測試紋波和噪聲。
1.2.3 Table 4 Output Transient Response. (輸出動態響應) Test condition.測試條件
Voltage Tolerance Limit |
Slew |
Load Change |
|
Rate |
|
+5.1VSB/±5%,+5.1V/±5% |
0.2A/uS |
Min. to 50% load and 50% |
+12V/±10%,+24V/±10% |
|
to Max load |
All output ±10% |
0.2A/uS |
Min. load to Max load | Note: Load change repetition rate: 50Hz to 100Hz . 跳變負載頻率:50~100Hz.
1.2.4 Table 5 Hold-Up Time(輸出保持時間)
Output |
120Vac input |
220Vac input |
Voltage |
|
|
+5.1VSB |
≥5 mS |
≥10 mS |
+5.1V |
≥5mS |
≥10 mS |
+12V |
≥5mS |
≥10 mS |
+24V |
≥5 mS |
≥10 mS | Note: All of dc output at rated load. 所有輸出帶額定負載。
1.2.5 Table 6 DC Output Overshoot During Turn-On & Turn-Off(輸 出超調)
Output Channel |
Output(V) |
Overshoot voltage(V)超調電壓 |
|
|
Turn-on 開機 |
Turn-off 關機 |
+5.1VSB |
+5.1V |
≤10% |
≤10% |
+5.1V |
+5.1V |
≤10% |
≤10% |
+12V |
+12V |
≤10% |
≤10% |
+24V |
+24V |
≤10% |
≤10% | Note: All of dc output current from Min. to Max. 測試時負載范圍:最小到最大。
1.2.6 Table 7 DC output voltage rise time(輸出上升時間)
Output |
120Vac input &Full Load |
220Vac input &Full Load |
Voltage |
|
|
+5.1VSB |
≤50 mS |
≤50 mS |
+5.1V |
≤100 mS |
≤100 mS |
+12V |
≤100 mS |
≤100 mS |
+24V |
≤100 mS |
≤100 mS | Note: The rise time measured is when the output voltages rise from 10% to 90% of specified output voltage Vout observed on the channel waveform.
上升時間為輸出電壓從 10%上升到 90%的時間。
1.3 Protection(保護功能)
1.3.1 Table 8 DC Output Over current Protection(輸出過流保護)
Output |
Over Current |
Comments |
Voltage |
|
|
+5.1VSB |
≥2.5Atyp* |
Hiccup 保護后重起 |
+5.1V |
≥4.5Atyp* |
Hiccup 保護后重起 |
+12V |
≥5.0Atyp* |
Hiccup 保護后重起 |
+24V |
≥6.0Atyp* |
Hiccup 保護后重起 | Note:The over current protection should be tested at other load rating.
過流保護測試是在其它額定負載時測試。
1.3.2 Table 9 DC Output Short Circuit Protection(輸出短路保護)
Output Voltage |
Comments |
+5.1VSB |
Hiccup 保護后重起 |
+5.1V |
Hiccup 保護后重起 |
+12V |
Shutdown 關機 |
+24V |
Shutdown 關機 | Note: The Short Circuit protection should be tested at other load rating.
短路保護測試是在其它額定負載時測試。 1.4 Table 11 Remote On/Off Control:(遙控功能)
The power supply DC outputs (without +5.1Vsb) shall be enable with an active-high TTL(≥2.5V/2.0mA)-compatible signal(Ps-on). The +5.1Vsb is on whenever the AC power is present.
除 5.1Vsb 外,其余輸出受控于一個 TTL 電平兼容的信號(Ps-on≥2.5V/2.0mA),
5.1Vsb 上電就存在。
* When Ps-on is pulled to TTL high, the DC outputs are to be enabled.
Ps-on 高電平,打開輸出
*When Ps-on is pulled to TTL low or open circuit, the DC outputs are to be disabled. Ps-on 低電平,關閉輸出
Ps-on Signal |
Comments |
Outputs |
Ps-on- high |
≥2.5V&2.0mA ( source) |
Output |
Ps-on- low |
≤ 0.5V |
X |
Ps-on-open |
-- |
X | 2. Isolation(絕緣性能) 2.1 Table 12 (絕緣阻抗)
Input To Output |
DC500V 10M Ω min (at room temperature) |
Input To FG |
DC500V 10M Ω min(at room temperature) |
Output To FG |
Non Isolated | Note: Open FG and Output return. 交流地和輸出負極要斷開。
2.2 Table 13 (絕緣耐壓)
Input To Output |
3000Vac 50Hz 1minute ≤10mA |
Input To FG |
1500Vac 50Hz 1minute ≤10mA |
Output To FG |
Non Isolated | Note: Open FG and Output return. 交流地和輸出負極要斷開。
3. Safety (安全規格)
The power supply shall comply with the following criterion:
電源安全性滿足下列標準: 1) IEC/EN60065
2) GB8898
3) UL60065
4. EMC (電磁兼容性)
4.1 EMI (電磁干擾)
The power supply shall comply with the following criterion:
電源電磁干擾滿足下列標準:
1) Conduction Emission : (傳導干擾度)
*CISPR13(55013)
*EN55013
*GB13837 *FCC PART13
2) Radiated Emission : (輻射干擾度)
*CISPR13(55013)
*EN55013
*GB13837 *FCC PART13
Note:The power board should be assembled in customer product to test for passing the above criterion.需配合用戶電路整機通過上述標準。
4.2 EMS (電磁抗擾)
The power supply shall comply with the following criterion:
電源電磁抗擾滿足下列標準:
1) ESD (靜電抗擾度)
*GB17626.2
*IEC/EN61000-4-2
2) EFT (脈沖群抗擾度)
*GB17626.4
*IEC/EN61000-4-43KV
3) SURGE (雷擊浪涌)
*GB17626.5
*IEC/EN61000-4-51.5KV/3KV
4) DIP (電壓跌落)
*GB17626.11
*IEC/EN61000-4-11 5. Environmental Requirement (工作環境)
5.1 Temperature (環境溫度)
Ø Operating 工作溫度: -10℃ to +40℃.
Ø Storage 存儲溫度: -20℃ to +80℃.
5.2 Humidity (環境濕度)
Ø Operating 工作: from 10%to90% relative humidity (non-condensing).
Ø Storage 存儲: from 5 to 95% relative humidity (non-condensing).
5.3 Altitude (海拔高度)
Ø Operating: to10,000 ft.
Ø Storage: to 20,000ft.
5.4 Cooling Method (冷卻方式)
Ø Ventilation cooling . 風道自然冷卻
5.5 Vibration (振動耐受)
Ø 10-55Hz, 19.6m/s²(2G), 20minutes each along X, Y and Z axis.
5.6 Shock(沖擊耐受)
Ø 49m/s²(5G),11ms, once each X, Y and Z axis.
6. Dimension (物理尺寸)
Ø 185mm X 131mm X 25mm(元件面高) (長 L *寬 W * 高 H ).
7. Weight (重量)
Ø 約 250 g
8. Pin Connection (連接器腳位定義)
Table 14 CON1(3Pin)
NO. |
Pin Connection |
Function |
① |
AC-L |
AC INPUT LINE |
② |
--- |
NC |
③ |
AC-N |
AC INPUT NUTURE | Note: CON1 -- VH CONNECTION, TYPE : pitch3.96mm
Table 15 CON2(13Pin)
NO. |
Pin Connection |
Function |
①②⑨⑩⑪ |
GND |
GND |
③④ |
5.1V |
+5.1V DC OUTPUT |
⑤ |
PS |
SMPS ON/OFF CONTROL(ON = HIGH) |
⑥ |
5.1VSB |
+5.1VSB DC STANDBY |
⑦⑧ |
5.1V |
+5.1V DC OUTPUT |
⑫⑬ |
+12V |
+12V DC OUTPUT | Note: CON2 --XH CONNECTION, TYPE : pitch2.5mm
Table 16 CON3(4Pin)
NO. |
Pin Connection |
Function |
①② |
+24V |
+24VDC OUTPUT |
③④ |
GND |
+24VDC RETURN | Note: CON3 -- XH CONNECTION, TYPE : pitch2.5mm
Table 18 CON4(8Pin)
NO. |
Pin Connection |
Function |
①②③④ |
+24V |
+24VDC OUTPUT |
⑤⑥⑦⑧ |
GND |
+24VDC RETURN | Note: CON3 -- XH CONNECTION, TYPE : pitch2.5mm
|
|